Benutzer-Werkzeuge

Webseiten-Werkzeuge


bakon-950d

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Nächste Überarbeitung
Vorhergehende Überarbeitung
bakon-950d [2015/10/02 07:40] – angelegt karlbakon-950d [2015/10/05 23:53] (aktuell) karl
Zeile 2: Zeile 2:
  
 This soldering station is quite interesting, especialy for that price. \\ I got it for about 35€ plus 13€ for 5 extra tips.  This soldering station is quite interesting, especialy for that price. \\ I got it for about 35€ plus 13€ for 5 extra tips. 
 +  - [[http://www.ebay.at/itm/Portable-Electronic-SMD-Soldering-Station-BAKON-950D-Solder-Iron-T12-Tip-75W-/171863535111?var=&hash=item2803dd6e07|Soldering Station, from eBay-user: vst-store]]
 +  - [[http://www.ebay.at/itm/Kit-5-Panne-De-Rechange-Solder-Tip-Fer-A-Souder-T12-BC2-T12-I-T12-B-T12-K-T12-24-/321838104023?|Soldering Tips, from eBay-user: zqualj]]
  
 The tips have the ceramic heating element included.  The tips have the ceramic heating element included. 
Zeile 8: Zeile 10:
  
 This design has 2 major disadvantages:  This design has 2 major disadvantages: 
-  - Every tip has its own heating element, with it's own characteristic. Therfore there is allways a different temperature error. I have measured 6 different tips with a thermocouple temperature sensor at a constant setting of 400°C. The results were between 335C° and 365°C. \\ As a workaround one can use a lookup table for each tip, which is a bit unpractical. +  - Every tip has its own heating element, with it's own characteristic. Therfore there is allways a different temperature error. I have measured 6 different tips with a thermocouple temperature sensor at a constant setting of 400°C. The results were between 335C° and 365°C. \\ As a workaround one can use a lookup table for each tip, which is a bit unpractical. \\ Edit: there is an adjustment potentiometer at the controller. Therefore the Error can be reduced to about ±15°C
   - Since the temperature is measured in the heating wire, that wire is held at a constant temperature. Due to the thermal resistance from the wiire to the tip a big temperature drop is the result on heavy thermal loads. Numerically spoken: The thermal power is reduced by 60%, compared to the ERSA Multi-TC, which has also a nominal power of 75W and a dedicated temperature sensor behind the tip.    - Since the temperature is measured in the heating wire, that wire is held at a constant temperature. Due to the thermal resistance from the wiire to the tip a big temperature drop is the result on heavy thermal loads. Numerically spoken: The thermal power is reduced by 60%, compared to the ERSA Multi-TC, which has also a nominal power of 75W and a dedicated temperature sensor behind the tip. 
bakon-950d.1443764433.txt.gz · Zuletzt geändert: 2015/10/02 07:40 von karl